How to Operate Mini Portable Oxygen Concentrator (POC2000 Inogen One G2 ReactHealth POC 2000 Rhythm
Here is a step-by-step guide on how to operate the Inogen One G2 Portable Oxygen Concentrator (POC2000):
1. Unpacking and Setup
Check the Contents: Ensure you have the concentrator, AC power supply, DC power cable, batteries, and carrying case.
Inspect for Damage: Before use, inspect the device and all accessories for any damage.
2. Powering On
Connect the Battery: Slide the battery into the bottom of the unit until it clicks into place.
Charging: Plug in the AC power supply into a wall outlet and connect it to the concentrator to charge the battery. The green light on the power adapter indicates the unit is charging.
Alternative Power: You can also use the DC power cable to charge the unit from a car or other DC power source.
3. Attaching the Nasal Cannula
Connect the nasal cannula tubing to the oxygen outlet port on the top of the unit.
4. Turning the Unit On
Press the ON/OFF button: Press and release the power button located on the front panel of the concentrator.
You will hear a series of beeps, and the display screen will light up, showing the current oxygen setting.
5. Adjusting the Oxygen Flow
Flow Settings: The Inogen One G2 delivers oxygen in pulse doses. Use the “+” or “-” buttons to adjust the oxygen flow rate to the level prescribed by your doctor (from 1 to 5).
The display will show the selected flow rate.
6. Monitoring the Device
The screen will display important information, such as battery life and current flow setting.
The unit will pulse oxygen as you breathe in, delivering oxygen only when inhaling.
7. Operating on Battery Power
If you are not using AC or DC power, the device will run on its internal battery.
Monitor the battery indicator on the display screen. When the battery is low, you’ll need to charge it or replace it with a fully charged one.
8. Charging the Battery
AC Power: Plug the concentrator into an AC outlet using the AC power adapter to charge the battery.
DC Power: Plug the concentrator into a vehicle’s DC outlet using the DC power cable.
It typically takes 3-4 hours to fully charge a battery.
9. Turning the Unit Off
Press the ON/OFF button: Hold the power button down for a few seconds until the display turns off and the unit powers down.
10. Additional Features
Alarms: The unit may sound an alarm for various reasons, such as low battery, no breath detected, or other system issues. Follow the screen prompts or refer to the user manual to resolve these alarms.
Carrying Case: The unit comes with a carrying case for portability. Ensure proper airflow around the device when using the carrying case.
11. Safety Precautions
Avoid Open Flames: Do not use the device near open flames or while smoking.
Keep Vents Clear: Make sure the intake and exhaust vents on the concentrator are not obstructed.
12. Maintenance
Cleaning: Regularly clean the nasal cannula, and wipe down the exterior of the device with a damp cloth.
Filter Replacement: Refer to the user manual for guidance on how and when to replace the filters.
For specific troubleshooting and further details, refer to the user manual that comes with the Inogen One G2 (POC2000) or contact the manufacturer for support.